Seitenansicht 65
58 9800/9820 Pump Dispenser Pump Interface Manual v1.3
Gasboy CFN Series 03/20/03
9 9800/9820 Pump Dispenser
Requirements
RS-485 PCB is required for all CFNs (1-3).
Pulser Interface PCB is required for Series 1000, System ‘A’, or other outside card sys-
tems (i.e. Petrovend).
C06394 CPU will work in place of any of the 7 other versions.
C06397 power supply will work in place of other 3 versions.
CPU Board
LED Indicators
Jumpers
Jumper K1 is set according to the size of the RAM IC in socket U19. At this time, only the 2K
size is being used:
LED Function
L1 AUTH1 - side 1 AC authorization present
L2 SLOW1 - side 1 slow flow solenoid
L3 FAST1 - side 1 fast flow solenoid
L4 SUBM1 - side 1 submersible starter relay
L5 AUTH2 - side 2 AC authorization present
L6 SLOW2 - side 2 slow flow solenoid
L7 FAST2 - side 2 fast flow solenoid
L8 SUBM2 - side 2 submersible starter relay
L9 PUL1A - side 1 pulser, channel A
L10 PUL1B - side 1 pulser, channel B
L11 HAND1 - side 1 handle switch
L12 PUL2A - side 2 pulser, channel A
L13 PUL2B - side 2 pulser, channel B
L14 HAND2 - side 2 handle switch
RAM Jumper Pins
2K across 2 and 3
8K across 1 and 2
Seitenansicht 65