28 Gilbarco Interface Unit Pump Interface Manual v1.3
Gasboy CFN Series 03/20/03
Position 5 is CLOSED if you wish to enable grade restrictions for fleet or club cards. This option
is available only at sites where all multi-fuel pumps are Advantage
.
Position 6 setting must agree with the configuration of every pump on an interface. Available
with Gilbarco firmware version 2.1 or above, position 6 sets digit monetary amounts, OPEN for
5 digit amounts, CLOSED for 6 digit money amounts.
Switch 3-5: Must be closed for Product Auth feature that is in v2.0C and above firmware.
Switch 3-4: with Site Controller versions before 2.0b, pumps are deactivated if offhook, and
activated if onhook. This is the sequence reported with push-to-start and cash-credit.
DIP Switch Bank 4
This switch selects certain price level options and allows either twelve or sixteen pumps (six or
eight double-sided units) on a loop. 5-8 are not used.
Dip Switch Bank 4 for a single-display price bar:
Dip Switch Bank 4 for a cash/credit select button, dual-display price bar, or a single alternating-
display price bar (only three prices levels—0, 1, and 2—can be loaded, and level 0 must be the
same as level 1 or level 2):
Baud Rate 3-1 3-2
9600 open open
2400 open closed
1200 closed open
300 closed closed
Position & Definition Setting(*=customary)
1 (see next table)
2 # of pumps per loop *open=6 dual pumps
closed=8 dual pumps
3 dead man timer *open=enabled
closed=disabled
4 (see next table)
5-8 ____
Pricing policy
Bar shows
level: SW4-1 SW4-4
all levels have same price 1
2
op
op
cl
op
level 1 same as level 2 1
2
op
op
cl
op
level 0 same as level 1 1
2
op
op
cl
op
levels 0, 1, and 2 all different 1
2
cl
cl
cl
op
Pricing policy SW4-1 SW4-4
level 0 same as level 1 op cl
level 0 same as level 2 op op