56 Pump Control Unit Pump Interface Manual v1.3
Gasboy CFN Series 03/20/03
DIP Switch Bank C
Jumpers
I/O Board
The part number of the original PPC I/O board is C05668.
Address B-1 B-2 B-3 B-4 B-5 B-6
1 clclclclclcl
2 opclclclclcl
3 clopclclclcl
4 opopcl cl cl cl
5 clclopclclcl
6 opclopclclcl
7 clopopclclcl
8 opopopcl cl cl
9 clclclopclcl
10 op cl cl op cl cl
11 cl op cl op cl cl
12 op op cl op cl cl
13 cl cl op op cl cl
14 op cl op op cl cl
15 cl op op op cl cl
16 op op op op cl cl
Baud Rate B-7 B-8
not used closed closed
9600 open closed
1200 closed open
300 open open
Position & Definition Setting(*=customary)
1-4 pulser enabled
pumps 1-4
*closed=after reset is complete
open=upon activation
5 CRC required *open=required
closed =not required
6 dead man timer *always open=enabled
7 ____
8 test mode *closed=no
open=yes
Jumper Setting-IN Setting-OUT Default
K1 normal battery test installed
K2 battery no battery installed