
50 SDI/Wayne CAT Interface Pump Interface Manual v1.3
Gasboy CFN Series 03/20/03
The first display in the self test shows:
REV XXX XX/XX/XX
ADDRESS = XX
The top row is the Vista Card terminal software revision level and the bottom row is the
currently assigned terminal address for the card processing terminal communication data link.
The top line must display the revision level of 50 or greater.
Press to exit.
Follow the instructions in the manual Installation Operation, Vista Series from Wayne
Dresser for completing the self test.
Site Controller Software Configuration
Version 2.2 or later of the SCII or version 3.0 or later for the CFN3 software is required to run a
Wayne CAT. The CAT should be on the RS-422 port.
All readers that are to be CATs must be set up in the Reader configuration to be device type
Wayne CAT. The Reader Parameter “TYPE” (device type) must be changed to 8, for Wayne
CAT.
Reader Addresses
No reader can be set to the address of 30, that is reserved for the Master Security Module. The
reader that would have been 30, give the address of 40. The Site Controller will read the address
as 30.
Keypad
The keys of the CAT keypad can be configured for different functions with the Tokheim DPT/
Wayne CAT keyboard layout item on page 4 of the Site Controller’s SYS_PAR program. The
characters that select different functions are shown below. Note that these characters are case-
sensitive:
Character Function
0-9 Numeric digits 0-9
. Decimal point
E ENTER
CCLEAR
YYes
NNo
$ Cash inside
cCash outside
D Debit inside
d Debit outside
B Credit (bank card inside)
b Credit outside
X CANCEL
x CLEAR/CANCEL (CLEAR if data entry started; else CANCEL)
HHelp
h Help/Decimal (Decimal if data entry started; else Help)
n No/CANCEL (No if in yes/no state; else CANCEL)
SStart
u unused key
ENTER
Kommentare zu diesen Handbüchern