Gasboy 1000 Series FMS Startup Manual Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Gasboy 1000 Series FMS Startup Manual herunter. Gasboy 1000 Series FMS Startup Manual User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - GASBOY INTERNATIONAL LLC

SERIES 1000 FUEL MANAGEMENT SYSTEM START-UP MANUAL C08921 GASBOY INTERNATIONAL LLC

Seite 2

03/07/03 2-1 Section 2 SITE INFORMATION Before you can use the Series 1000, you must load in certain operating information. This section provi

Seite 3

GASBOY Series 1000 2-2 03/07/03 Pump No. Pulser Type (Reed, Elec.) Pulses Per Gallon ($, 1000, 500, 100, 10, 1) Tank Number (1-8) Fuel Code (1-99)

Seite 4 - CONTENTS

Site Information 03/07/03 2-3 5. PRODUCT AUTHORIZATION TABLE (Reference: Operation Manuals: LF Command) Card Encoding Manual: Product Authori

Seite 5

GASBOY Series 1000 2-4 03/07/03 7. LOCKOUT TYPE (Reference: Operation Manual: VA and IA Commands) Check type of lockout desired: Negative ___

Seite 6 - Section 1

Site Information 03/07/03 2-5 9. SECOND ACCOUNT FIELD AND PIN DATA (Reference: Operation Manual) Use of the second account field is optional a

Seite 7 - WHAT YOU NEED FOR TESTING

GASBOY Series 1000 2-6 03/07/03 FLEETKEY SYSTEMS ONLY 10. MAINTENANCE TABLE (Reference: FleetKey Operation Manual: Maintenance Option) MAINT

Seite 8 - USING THIS BOOK

03/07/03 3-1 Section 3 BEGIN START-UP FORM PARTS 1 THROUGH 4 This section covers Parts 1 through 4 of the Start-up form. Parts 5 through 12

Seite 9

GASBOY Series 1000 3-2 03/07/03 ✍ 3. COMMUNICATION Data Terminal: The make and model number of the data terminal connected to the system. If a d

Seite 10 - SITE INFORMATION

03/07/03 4-1 Section 4 SYSTEM LAYOUT 1. Verify that the system is installed with a minimum clearance of 18 inches between the post and any of

Seite 11

GASBOY Series 1000 4-2 03/07/03 ✍ 5. CONDUIT All Metal Conduit: Indicate if all conduit is metal and not PVC. Circle Y for yes (all metal) or N

Seite 12

GASBOY SERIES 1000 FUEL MANAGEMENT SYSTEM START-UP MANUAL C08921 Rev. 03/07/03 GASBOY INTERNATIONAL LLC LANSDALE, P

Seite 13

03/07/03 5-1 Section 5 JUMPER AND SWITCH SETTINGS SERIES 1000 JUMPERS All jumpers and connectors must be set properly to ensure correct operat

Seite 14

GASBOY Series 1000 5-2 03/07/03 2. Unlock and lower the rear door of the Series 1000. 3. Make sure the Series 1000 AC POWER switch, located in t

Seite 15

Jumper and Switch Settings 03/07/03 5-3 Figure 5-2. Series 1000 Microprocessor Configuration

Seite 16 - BEGIN START-UP FORM

GASBOY Series 1000 5-4 03/07/03 15. If your Series 1000 system has a Tripp Lite battery backup installed, remove the jumper or wire wrap on jumper

Seite 17

Jumper and Switch Settings 03/07/03 5-5 Figure 5-3. Series 1000 Pump Control Configuration

Seite 18 - SYSTEM LAYOUT

GASBOY Series 1000 5-6 03/07/03 AUXILIARY COMMUNICATIONS PORT PCB ASSEMBLY When the system is equipped with a receipt printer, tank monitoring sys

Seite 19

Jumper and Switch Settings 03/07/03 5-7 The TLS-250 Main PCB is located in the back of the TLS-250 box and accessed by opening the right hinged cov

Seite 20 - JUMPER AND SWITCH SETTINGS

GASBOY Series 1000 5-8 03/07/03 GASBOY FUEL POINT READER SWITCHES When the system is used with the Fuel Point Reader (FPR), verify that the switch

Seite 21

Jumper and Switch Settings 03/07/03 5-9 LINK MC5 TERMINAL SETUP Install and complete the setup of the terminal as specified in the manufacturer’s

Seite 22 - 03/07/03 5-3

GASBOY Series 1000 5-10 03/07/03 3. Press F2 or PAGE DOWN to display the next Setup Screen, Communications Setup. NOTE: Series 1000 software pr

Seite 23

Copyright 2003 by Gasboy International LLC All rights reserved The information in this document is confidential and proprietary.

Seite 24 - 03/07/03 5-5

Jumper and Switch Settings 03/07/03 5-11 6. Press F5 or PAGE DOWN to display the next Setup Screen, ANSI Setup. 7. Press S to save Setup changes

Seite 26

03/07/03 6-1 Section 6 PUMP/DISPENSER MANUAL TEST 1. Verify that the general guidelines listed below were met when installing the system’s pum

Seite 28 - LINK MC5 TERMINAL SETUP

03/07/03 7-1 Section 7 SYSTEM POWER 1. Verify that the AC Power for the Series 1000 System comes from a separate, dedicated circuit breaker.

Seite 30 - OKIDATA 184 SETUP

03/07/03 8-1 Section 8 DC POWER SERIES 1000 1. Turn on the system AC POWER switch located in the rear of the unit. The fluorescent lamp shou

Seite 31

GASBOY Series 1000 8-2 03/07/03 +12VDC Measure to the +12 red test point. The tolerance for this voltage is +11.8 to +14.00 and is not adjustabl

Seite 32 - PUMP/DISPENSER MANUAL TEST

03/07/03 9-1 Section 9 COMMUNICATIONS TESTS 1. Verify that the external communication devices are located in the proper environments as descri

Seite 33

GASBOY Series 1000 9-2 03/07/03 Testing the Direct Connect Device a. Turn on the direct connect device (e.g., data terminal). b. Locate t

Seite 34 - SYSTEM POWER

03/07/03 1-1 CONTENTS Section 1: STARTING A SERIES 1000 SYSTEM Introduction...

Seite 35

Communications Tests 03/07/03 9-3 Testing the Tank Monitor a. Determine the device (direct connect or modem) from which the tank monitor will

Seite 37 - GASBOY FUEL POINT READER

03/07/03 10-1 Section 10 PUMP/DISPENSER AUTOMATIC TEST The automatic test verifies the wiring and operation of the system in respect to the con

Seite 38 - COMMUNICATIONS TESTS

GASBOY Series 1000 10-2 03/07/03 13. Repeat Steps 9 through 12 for all combinations of hose outlets of the same product type. 14. Replace and l

Seite 39

03/07/03 11-1 Section 11 START-UP COMMANDS Use the following commands to set up the system at the initial start-up. The Series 1000 Operation

Seite 40

GASBOY Series 1000 11-2 03/07/03 4. Type SC to load your system configuration data. CARD OR CARDLESS SYSTEM * ↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵ NOTE: Addit

Seite 41

Start-Up Commands 03/07/03 11-3 FLEETKEY SYSTEM * ↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵↵

Seite 42 - Section 10

GASBOY Series 1000 11-4 03/07/03 5. For FleetKey systems only, type CT to clear the key receptacle read and error table. ↵ 6. Type RT to initiali

Seite 43

Start-Up Commands 03/07/03 11-5 10. For Card or Cardless systems only, type LK to load the 4-digit PIN key that is assigned to your system at the

Seite 44 - START-UP COMMANDS

GASBOY Series 1000 11-6 03/07/03 13. Type LI to assign the initial inventory of each tank. For example, if Tank 2 currently contains 1700 gallons,

Seite 46 - 03/07/03 11-3

Start-Up Commands 03/07/03 11-7 16. Type LF to assign the fuel codes to the proper authorization codes. For initial start-up, assign fuel codes to

Seite 47

GASBOY Series 1000 11-8 03/07/03 18. For cardless systems only, type CV to clear the vehicle file of any test data that may be present. ↵ 19. F

Seite 48

03/07/03 12-1 Section 12 CUSTOMER TRAINING 1. Explain to the terminal operator how the CRT terminal responds to commands. Review all relevant

Seite 50

03/07/03 13-1 Section 13 FINISH START-UP 1. Unlock and lower the rear door of the Series 1000 head assembly. 2. Move the Pulse Rate switch

Seite 51

GW01 - 6/04/02 Rev. 1 WARRANTY General Statements: Gasboy International LLC. warrants all new equipment manufactured by Gasboy against defective

Seite 52 - CUSTOMER TRAINING

55F-065 Rev. 7105 GASBOY SERIES 1000 START-UP FORM 1. SITE IDENTIFICATION Customer ________________________________ Date: ____________________

Seite 53

Please supply any additional customer comments in the space below: _______________________________________________________________________________

Seite 54 - FINISH START-UP

03/07/03 1-1 Section 1 STARTING A SERIES 1000 SYSTEM INTRODUCTION This Start-Up Manual is provided to assist you in the start-up of a GASBOY

Seite 55 - WARRANTY

GASBOY Series 1000 1-2 03/07/03 START-UP OVERVIEW Start-up for the Series 1000 System consists of: • verifying the system layout • making sure

Seite 56 - 55F-065 Rev. 7105

Starting a Series 1000 System 03/07/03 1-3 USING THIS BOOK This book is designed to be followed from start to finish. The procedures are listed i

Kommentare zu diesen Handbüchern

Keine Kommentare