9862 DEF units.
Frozen Condition: The coriolis interface board monitors the temperature at the
solenoid valve using the temperature sensor known as the frozen thermostat. The
purpose is to remove power to signal the 9800 CPU board not to active the solenoid
valve on the coriolis meter. This prevents the solenoid valve to potentially leak and
also prevent damage to the coriolis meter.
The CR5 LED on the coriolis interface board will light when a freeze condition
exists, which is normally caused by other component failure, causing the heaters
not to turn on as shown Figure 4-1.
Calibration Test: When the freeze problem has been
corrected and the heater/fans are working, to keep the inside
cabinet temperature in 30° F (-1.1° C) range or higher, you
need to recalibrate the unit to remove the error message 999
displayed.
Symptoms: In very cold weather conditions, the display shows 999 and is unable to dispense product.