MDE-5044A Atlas® DEF Operation, Diagnostics, and Recommended Spare Parts Manual · April 2014 Page 3-1
Fueling Process Operation Modes
3 – Operation Modes
Fueling Process
Fueling at Idle State
When the dispenser is at idle state, the following will occur while fueling:
Electronic head-assembly displa
y shows the last sale or a decimal point.
Dispenser is in the prime state and urea is at the i
ntake of the Solenoid Valve
(M02321A005).
The nozzle is removed from a cold weather dispenser or
handle is turned on a warm
weather dispenser.
Display resets and shows all 8s, then 0s with decimal point.
Solenoid valve opens (with an audible click).
Nozzle is inserted into the tank labeled for urea.
Nozzle is squeezed and product is dispensed.
Display shows the amount of product being dispensed.
Nozzle is turned off and product stops
dispensing.
Nozzle is returned to the cradle or
the handle is turned off.
Solenoid valve closes and the fueling transaction is terminated.
Display shows the total amount of product dispensed.
Cold Weather DEF Dispenser
Following will occur in cold weather DEF unit while fueling:
The dispenser is primed and the product is at the intake of the sol
enoid valve.
When the nozzle is removed, sensor switch sends signal to 9800 Central Proc
essing Unit
(CPU) Board (M06333KECAL):
- Side 1 “Handle” Light Emitting Diode (LED) lights.
- Customer display shows all 8s, then 0s with decimal point.
- Side 1 “Fast”, “Slow”,
“Sub” LEDs light.
- Submersible motor activates in the tank.
- 9800 CPU board sends the AC hot signal to the solenoid valve.
- Solenoid valve opens.
The product flows and enters into the Coriolis
Meter/Pulsar Assembly (M10006B501) and
then to the nozzle (hose jumps).
When the nozzle is opened, product starts to flow.
The coriolis meter senses and monitors the product flow and
sends the pulse signal to the
Coriolis Meter Interface Board (M10030A001) and then to the 9800 CPU board.
The pulse A LED flashes for pump #1 on the 9800 CPU board.
If the optional Dual Pulse Input/Outp
ut (I/O) Board (M06587A001) is attached to the
9800 CPU board, the two pulsar LEDs will flash when product flow is detected.
When fueling stops, pulsar LEDs on the 9800 CPU board and optional dual pulse I/O
board stop flashing.
Customer display shows the total amoun
t of product dispensed in gallons.
Nozzle is placed back into the cradle, dispense
r motor stops, and the solenoid valve closes.
The fast, slow, and sub LEDs on the 9800 CPU board
are now OFF. END OF
TRANSACTION.
The DEF nozzle with the blue cover requires a magnetic actuator to dispense the
product. The DEF nozzle with the black cover does not require a magnetic actuator.