MDE-4298D CFN Series Site Controller III Installation Manual · September 2009 Page 55
Wiring Diagrams Pump/Remote Dispenser Wiring
Pulser Wiring Requirements
18 AWG wires are required for the installation of a pulser in a separate DC conduit. Although
it is recommended that DC pulser wires be run in a conduit away from AC wires, they can be
combined in the same conduit with AC wires if a UL-listed cable with the following
specifications is used:
Conductor 18 AWG stranded wire. Number of conductors to be determined by the pulser.
Shield Foil-wrapped 100% coverage and/or tinned copper braid 90% coverage
Drain Wire Stranded, tinned copper, 20 AWG or larger/or braided shield
Voltage Rating Maximum operating voltage of 600 V
Environmental Gas and oil-resistant; suitable for wet or dry locations
Gasboy can supply Belden 1063A (Part Number C09655) which is a UL-listed, 4-conductor
cable that meets the requirements listed above.
Note: Belden 1063A is UL-listed but not CSA-listed.
Wiring Diagrams
This section contains the following wiring diagrams.
Figure 5-9: Single Suction Pump, VR Reset on page 56
Figure 5-10: Twin Suction Pump, VR Reset on page 57
Figure 5-11: Twin Suction Pump, Single Motor, VR Reset on page 58
Figure 5-12: Single Remote Dispenser, VR Reset on page 59
Figure 5-13: Twin Remote Dispenser, VR Reset on page 60
Figure 5-14: Single Suction Pump, Console, VR Reset on page 61
Figure 5-15: Twin Suction Pump, Console, VR Reset on page 62
Figure 5-16: Twin Suction Pump, Single Motor, Console, VR Reset on page 63
Figure 5-17: Single Remote Dispenser, Console, VR Reset on page 64
Figure 5-18: Twin Remote Dispenser, Console, VR Reset on page 65
Figure 5-19: Single Suction Pump, Gasboy Reset on page 66
Figure 5-20: Twin Suction Pump, Gasboy Reset on page 67
Figure 5-21: Twin Suction Pump, Single Motor, Gasboy Reset on page 68
Figure 5-22: Single Remote Dispenser, Gasboy Reset on page 69
Figure 5-23: Twin Remote Dispenser, Gasboy Reset on page 70
Figure 5-24: Single Suction Pump, Console, Gasboy Reset on page 71
Figure 5-25: Twin Suction Pump, Console, Gasboy Reset on page 72
Figure 5-26: Twin Suction Pump, Single Motor, Console, Gasboy Reset on page 73
Figure 5-27: Single Remote Dispenser, Console, Gasboy Reset on page 74
Figure 5-28: Twin Remote Dispenser, Console, Gasboy Reset on page 75