GASBOY Series 1000
2-40 03/07/03
3. Figure out the number of RAM bytes used. Add the calculation totals of each option selected
and write the sum in the space provided at the bottom. This is your RAM Total.
OPTIONS CALCULATIONS
MPG/HPG w/Reas. Odom/Hours*
(Number of Vehicles _____
x (Vehicle Bytes _____ + 13)) + 46 =
Reas. Odom/Hours only*
(Number of Vehicles _____ x (Vehicle Bytes _____ + 5)) + 46 =
Fuel Allocation (Number of Totalizers _____ x 4) + 44 =
Dual Lockout
+ 1260 =
Receipt Printer
+ 856 =
Tank Monitor
+ 506 =
Supervisor Cards + 12 =
Extended Pump Timeouts
+ 58 =
Pump Switch Timer + 11 =
Fuel Delivery & Dipstick + 6 =
Multi-Level Password + 63 =
Loadable Base Pump + 4 =
AP w/Data Entries + 9 =
RAM Total
=
* You calculated the size of your vehicle field in bytes in Step 1 (Digits
+ 1)
÷
2. Vehicle will be
Field 1, Field 2 or Manual Entry field depending on how you ordered your system.
4. Figure out the amount of available transaction space.
Write the following values: ROM TOTAL (From Step 2):
RAM TOTAL (From Step 3):
Consult the following chart to see where your ROM value falls.
ROM TOTAL RANGE BYTES
22513 to 26608 4096
26609 to 30704 8192
30705 to 34800 12288
over 34800
*
*
If your ROM TOTAL exceeds this number, your system has too many options. Eliminate options.
Write the number listed in the BYTES column:
Perform the following calculation:
RAM Total
+ Bytes = Reserved RAM
+ =