GASBOY Series 1000
2-38 03/07/03
TRANSACTION STORAGE CALCULATION
If the configuration of variable field sizes and software options you have is not listed in the
transaction storage table, you can determine the approximate number of transactions by
calculating:
1. The number of bytes in your transaction record.
2. The number of ROM bytes used.
3. The number of RAM bytes used.
4. The available transaction space
5. The total number of transactions that can be stored.
The calculations vary according to the type of system you have (mag, optical, or CFN Network).
Calculations for each system type can be found in the following subsections.
Mag Card Systems
1. Figure out the number of bytes in the transaction record. Only add in the calculations for
manual entry, MPG/HPG, and receipt printer if you have these options.
Field 1 (_____ digits + 1) / 2 (drop decimal remainder) =
Field 2 (_____ digits + 1) / 2 (drop decimal remainder) =
Manual Entry (_____ digits
+ 1) / 2 (drop decimal remainder) =
MPG/HPG Add 2 =
Receipt Printer Add 1
=
+ 22
Number of Bytes in Transaction Record (Add column) =